【Power(W)】50W,65W,75W【Maximum output voltage(kV)】
 

PCB drilling target drone - Oxford Seiko XRW50P50 high voltage power supply

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2017-12-26 04:46
Browse the number: 155
inquiry
Company Profile
 
 
Product details
【Type】 XRW
【Power(W)】 50W,65W,75W
【Maximum output voltage(kV)】 ,20,25,30,35,40,50,60,65,

 

Selection Wisman, enjoy the best services in the world... To..

Raw materials procurement to ensure that the products of best quality.........

Wisman high voltage power index is measured out, not calculated, a $5000000 system.

Measuring equipment to ensure high voltage power indices.

Typical application:

ROHS tester, XRF tester: an alternative to XRM50P50X3839, XRM50P50X3768, XRM50P50X3491, XRM50P50X3465,

Elemental analysis: an alternative to XRM50P50X2871, XRM50P50X2810, XRM50P50X3830,

Thickness detection

X ray

Particle size measurement

Density measurement

The paper component detection

PCB appearance inspection machine

Crystal detector

X-RAY inspection machine

PCB drilling target drone

X ray fluorescence spectrometer, paper, film, foil thickness measurement, elemental analysis, X ray, particle size measurement, density measurement, the paper component detection, on-line process control, ROHS testing, thickness, printed circuit board inspection system, X ray fluorescence analysis, radiation radiography, X ray imaging, multilayer PCB counterpoint, particle size measurement, density measurement, process control, X ray spectroscopy, welding, wire head detection corresponding to the X (X-ray tube cathode or anode grounding):

Kevex, Oxford, RTW, Superior, Varian, Trufocus and domestic brands.

1.1 XRW Series Introduction

XRM series high voltage power supply for X ray tube provides advanced and complete solution.This power is not only provide high voltage output, also provides complete control signal and a variety of auxiliary functions, so as to meet the need of application of X ray tube.XRM series power can output a stable small ripple voltage and current, make its performance than previous techniques has greatly improved, with no increase in X ray tube load under the condition of better focus.

The series 1.2 XRW specification

Input: DC DC24V ± 10%, maximum current 4.25A.

Output: 20KV, 30KV, 50KV, 65KV four maximum voltage output optional, 0V to the highest voltage adjustable.

Voltage control:

The internal power supply: power supply with multiturn potentiometer can be output

Voltage setting in the 0V to the highest voltage

External remote control: external 0 to 10V control signals can be output

From the 0V to the maximum output voltage.

Emission current control:

The internal power supply: power supply with multiturn potentiometer can be set in the 0A electron beam current to a maximum current.

External remote control: external 0 to 10V control signals can be set in the 0A electron beam current to a maximum current.

DC filament power supply: output current of 0-3.5A adjustable voltage, adjustable for 0-5.5V.

Voltage regulation rate:

Relative load: 0.01% (no load to rated load)

The phase of input: ± 0.01% (input voltage change is ± 10%)

Current regulation:

Relative load: 0.01% (no load to rated load)

Relative to the input: ± 0.01% (input voltage variations of ± 10%)

Output ripple voltage: rated voltage condition, the ripple voltage peak value for the maximum output voltage 0.25%.

Temperature coefficient: 0.01% per degree celsius.

Stability: starting up half hours after every 8 hours less than 0.05%.

Voltage current instruction: 0 to +10V, rated output condition accuracy of 1%.

Environment temperature: 0 ℃ to +50 ℃ when working.Storage at -20 ℃ to +80 ℃.

Dimensions: length 254MM, width 100mm, high 160mm.

Weight: 4.8 kg.

Connector:

High voltage output connector: recessed insulating epoxy resin duct and into the high voltage cable through the diameter of 16mm metal connector.High voltage cable length of 1 meters.

Input output connector: DB9 contains the control and display signal.

Output voltage and current of the remote control: external potentiometer can be used inside power supply 10V reference voltage on the output voltage and current for remote control.

Remote voltage indication: JP4 contains 0 10V voltage and current indicative signal, can be externally connected with various number or pointer table.

1.3 standard function

The XRW series offers a standard function to meet the user's application and security needs.

High voltage, high current and filament current slow start function: this function makes the high voltage output, high voltage current and filament current according to the design requirements of slope rises smoothly, thereby prolonging the service life of X ray tube, usually the rise time is about 4 seconds, the filament current will rise slowly until the emission current at required level.When the output is the maximum value, this time is generally 4 seconds.The ramp starting conditions for the triggering of INTERLOCK control signal.

Light emitting diode lamp: green light-emitting diode power indicator, yellow for high voltage output off indicator, red for high voltage output indicator.

High voltage cable: standard power supply provides a 1 meters high voltage insulated cable, one end of the cable with a plug and a very easy to be fixed on the shell of the connector for power supply.For non standard power refer to diagram and description.

1.31 remote monitoring function:

Remote detection: by detecting the front panel of the KV MON and MON RTN and mA MON and MON RTN X ray tube voltage and emission current remote detection function.Standard products for the KV MON 1V=10KV, mA MON 1V=0.1 mA (other proportion of optional)